JDGuard 4431 Epoxy Anticorrosive Primer
Epoxy anti-corrosive primer for steel — the foundation coat of a Kindon marine or industrial protective system.
Diagram code: JDGuard4431
Series: Anti-corrosive · Layer: Anticorrosive primer
View productAn acrylic silane hydrolysis antifouling with a 60-month docking interval and 8% fuel saving.
Series: Antifouling Hull area: Vertical bottom, Flat bottom Coat layer: Antifouling finish Back to series →
An acrylic silane hydrolysis antifouling with a 60-month docking interval and 8% fuel saving.
Recommended for underwater hulls during newbuilding and dry-docking. It provides an optimized solution for vessels with low operating rates and slow steaming speeds. Application is highly recommended in areas requiring superior antifouling performance, such as sea chests, to minimize the risk of invasive species. This product offers optimized hull protection for vessels operating in heavily fouled waters or those subject to prolonged idle periods. When applied as part of a complete coating system, it can provide long-term protection for up to 90 months.
Marine: Recommended for the underwater hulls of new builds and dry-docking projects. It provides a highly optimized solution for vessels where long-term hull performance and fuel savings are the primary focus. As part of a complete coating system, this product can offer extended protection for up to 90 months. Protective Coatings: Recommended for immersion areas of offshore structures and stationary equipment.
•Compliant with IMO Antifouling System Convention AFS/CONF/26. •Obtained Works Approval for Ship Anti-fouling Paint from the China Classification Society
Red brown, red
| Property | Test/Standard | Description |
|---|---|---|
| Solids by volume | ISO 3233 | 57±2% |
| Flash point | ISO 3679 Method 1 | 28℃ |
| Density | calculated | 1.9Kg/L |
| VOC-China | GB/T23985-2009(ISO11890-1) | 369g/L |
| Touch dry(20℃) | 2 h |
The provided data is typical for factory produced products, subject to slight variation depending on colour.
Dry film thickness 75μm - 150μm
Wet film thickness 131μm - 263μm
Theoretical spreading rate 7.5 m2/L - 3.8 m2/L
To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any contamination.
| Substrate | Surface preparation | |||
|---|---|---|---|---|
| Minimum | Recommended | |||
| Coated surfaces | New tie coat or new antifouling: Remove any contamination that could interfere with the intercoat adhesion. Exceeding maximum recoat intervals will require cleaning/abrading and/or application of additional coats, depending on condition Aged antifouling with leached layer: Removal by thorough fresh water washing at minimum nozzle pressure 200 bar. | New tie coat or new antifouling: Remove any contamination that could interfere with the intercoat adhesion. Exceeding maximum recoat intervals will require cleaning/abrading and/or application of additional coats, depending on condition. Aged antifouling with leached layer: Removal by thorough fresh water washing at minimum nozzle pressure 340 bar. | ||
The product can be applied by Spray: Use air spray or airless spray. Brush: May be used. Care must be taken to achieve the specified dry film thickness. Roller: May be used. Care must be taken to achieve the specified dry film thickness.
Single pack
Thinner: Jindun Thinner No. 102
Nozzle tip (inch/1000): 21-31 Pressure at nozzle (minimum): 150 bar/2100 psi
The subsequent Painting interval time 5℃ 10℃ 20℃ 30℃ coating
Minimum coating interval 24 h 12 h 8 h 6 h time itself Minimum drying time before immersion in 24 h 16 h 12 h 8 h water
| Volume | Size of containers | |
|---|---|---|
| (L) | (litres) | |
| JDAF899 | 20 | 20 |
The volume stated is for factory made colours.
The product must be stored in accordance with national regulations. Keep the containers in a dry, cool, well ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle with care.
JDAF899 9 month(s) In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf life, thereafter the paint quality is subject to re-inspection.
This product is for professional use only. The applicators and operators shall be trained, experienced and have the capability and equipment to mix/stir and apply the coatings correctly and according to Jindun's technical documentation. Applicators and operators shall use appropriate personal protection equipment when using this product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit the site conditions shall be forwarded to the responsible Jindun representative for approval before commencing the work.
Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.
When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations from batch to batch. Such products and epoxy based products used as a finish coat may chalk when exposed to sunlight and weathering. Colour and gloss retention on topcoats/finish coats may vary depending on type of colour, exposure environment such as temperature, UV intensity etc., application quality and generic type of paint.
The information in this document is given to the best of Jindun's knowledge, based on laboratory testing and practical experience. Jindun's products are considered as semi-finished goods and as such, products are often used under conditions beyond Jindun's control. Jindun cannot guarantee anything but the quality of the product itself. Minor product variations may be implemented in order to comply with local requirements. Jindun reserves the right to change the given data without further notice. Users should always consult Jindun for specific guidance on the general suitability of this product for their needs and specific application practices.
Epoxy anti-corrosive primer for steel — the foundation coat of a Kindon marine or industrial protective system.
Diagram code: JDGuard4431
Series: Anti-corrosive · Layer: Anticorrosive primer
View productA surface-tolerant vinyl epoxy tie coat that bonds epoxy primers to antifouling systems on the underwater hull.
Diagram code: JDGuard5345
Series: Anti-corrosive · Layer: Tie coat
View productGeneral-purpose epoxy anti-corrosive paint for steel structures, hull internals and machinery exposed to marine and industrial atmospheres.
View productA high-solids, two-component aliphatic acrylic polyurethane topcoat with very good gloss retention and an excellent balance of hardness and flexibility.
Diagram code: JDThane7106S
Series: Anti-corrosive · Layer: Finish / topcoat
View productA fast-drying, one-component physically drying acrylic topcoat with a semi-gloss finish and good gloss retention.
Diagram code: JDAcrylic435
Series: Anti-corrosive · Layer: Finish / topcoat
View productA two-component solvent-free epoxy tank lining with good chemical resistance, qualified for potable-water contact.
Diagram code: 712SF
Series: Anti-corrosive · Layer: Tank lining (potable water)
View productTell us the substrate, service environment and area to be coated — we will confirm availability, lead time and the matching primer and topcoat.