View productA single-component chemically hydrolysing silyl methacrylate antifouling with a 60-month docking interval and 10% fuel saving.
Series: Antifouling Hull area: Vertical bottom, Flat bottom Coat layer: Antifouling finish Back to series →
A single-component chemically hydrolysing silyl methacrylate antifouling with a 60-month docking interval and 10% fuel saving.
This is a state-of-the-art, single-component chemically hydrolysing silyl methacrylate resin antifouling coating. It delivers superior antifouling protection, ultra-low frictional resistance, and unparalleled hull performance.This antifouling effect is achieved through highly predictable and stable self-polishing properties, which also minimize hull degradation and reduce friction and speed loss. Its initial ultra-smooth surface ensures excellent dry-docking performance.It is strictly intended for use as a topcoat in submerged environments and can be applied at surface temperatures below 0°C.
Marine: For underwater hull in drydocking and newbuilding for both sea and fresh water during outfitting. ECO-FRI896SL can be applied at sub-zero surface temperatures. ECO-FRI896SL is an ultra-premium solution for vessels whose main focus is verified high hull performance in predictable trades, cut carbon emissions, protect biodiversity, and preserve fuel. This antifouling coating is designed for long service periods and can be used up to 90 months as a part of a complete coating system.
Compliant with IMO Antifouling System Convention AFS/CONF/26. Type Approval Certificate for Antifouling Paint from the Russian Maritime Register of Shipping (RS)
Redbrown, red
| Property | Test/Standard | Description |
|---|---|---|
| Solids by volume | ISO 3233 | 52±2% |
| Flash point | ISO 3679 Method 1 | 25℃ |
| Density | calculated | 1.8Kg/L |
| VOC-China | GB/T23985-2009(ISO11890-1) | 420g/L |
| Touch dry(20℃) | 2 h |
The provided data is typical for factory produced products, subject to slight variation depending on colour.
Dry film thickness 75μm - 175μm Wet film thickness 144μm - 336μm Theoretial spreading rate 0.26Kg/m2 - 0.61Kg/m2 Max total DFT for multiple coats in the antifouling system: 600 µm
To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any contamination.
| Substrate | Surface preparation | |||
|---|---|---|---|---|
| Minimum | Recommended | |||
| Coated surfaces | New tie coat or new antifouling: Remove any contamination that could interfere with the intercoat adhesion. Exceeding maximum recoat intervals will require cleaning/abrading and/or application of additional coats, depending on condition Aged antifouling with leached layer: Removal by thorough fresh water washing at minimum nozzle pressure 200 bar. | New tie coat or new antifouling: Remove any contamination that could interfere with the intercoat adhesion. Exceeding maximum recoat intervals will require cleaning/abrading and/or application of additional coats, depending on condition. Aged antifouling with leached layer: Removal by thorough fresh water washing at minimum nozzle pressure 340 bar. | ||
| The product can be applied by | |
| Spray: | Use air spray or airless spray. |
| Brush: | May be used. Care must be taken to achieve the specified dry film thickness. |
| Roller: | May be used. Care must be taken to achieve the specified dry film thickness. |
Single pack
Thinner: Jindun Thinner No. 102
Nozzle tip (inch/1000): 21-31 Pressure at nozzle (minimum): 150 bar/2100 psi
| Substrate temperature | -10 °C | 0 °C | 10 °C | 23 °C | 40 °C |
|---|---|---|---|---|---|
| Surface (touch) dry | 8h | 2h | 45min | 30min | 30min |
| Dry to over coat, minimum | 27 h | 16 h | 9 h | 7 h | 6 h |
| Dried/cured for immersion | 39 h | 24 h | 10 h | 9 h | 8 h |
For maximum overcoating intervals, refer to the Application Guide (AG) for this product. The dried/cured for immersion data in the above table is the time required until the product is ready for sailing. For mechanical resistance to fenders and similar equipment longer drying times may be required. Please consult the Application Procedure for further advice. When high film thickness is applied the antifouling will stay soft longer. To enable hull roughness reading when two or more antifouling coats are applied in rapid succession it is recommended to double the minimum time for immersion. Drying and curing times are determined under controlled temperatures and relative humidity below 85 %, and at average of the DFT range for the product. Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal tackiness. Dry to over coat, minimum: The recommended shortest time before the next coat can be applied. Dried/cured for immersion: Minimum time before the coating can be permanently immersed in sea water.
| Weight | Size of containers | |
|---|---|---|
| (Kg) | (litres) | |
| ECO-FRI 896SL | 34 | 20 |
The volume stated is for factory made colours.
The product must be stored in accordance with national regulations. Keep the containers in a dry, cool, well ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle with care.
ECO-FRI 896SL 9 month(s) In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf life, thereafter the paint quality is subject to re-inspection.
This product is for professional use only. The applicators and operators shall be trained, experienced and have the capability and equipment to mix/stir and apply the coatings correctly and according to Jindun's technical documentation. Applicators and operators shall use appropriate personal protection equipment when using this product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit the site conditions shall be forwarded to the responsible Jindun representative for approval before commencing the work.
Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.
When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations from batch to batch. Such products and epoxy based products used as a finish coat may chalk when exposed to sunlight and weathering. Colour and gloss retention on topcoats/finish coats may vary depending on type of colour, exposure environment such as temperature, UV intensity etc., application quality and generic type of paint.
The information in this document is given to the best of Jindun's knowledge, based on laboratory testing and practical experience. Jindun's products are considered as semi-finished goods and as such, products are often used under conditions beyond Jindun's control. Jindun cannot guarantee anything but the quality of the product itself. Minor product variations may be implemented in order to comply with local requirements. Jindun reserves the right to change the given data without further notice. Users should always consult Jindun for specific guidance on the general suitability of this product for their needs and specific application practices.
Epoxy anti-corrosive primer for steel — the foundation coat of a Kindon marine or industrial protective system.
Diagram code: JDGuard4431
Series: Anti-corrosive · Layer: Anticorrosive primer
View productA surface-tolerant vinyl epoxy tie coat that bonds epoxy primers to antifouling systems on the underwater hull.
Diagram code: JDGuard5345
Series: Anti-corrosive · Layer: Tie coat
View productGeneral-purpose epoxy anti-corrosive paint for steel structures, hull internals and machinery exposed to marine and industrial atmospheres.
View productA high-solids, two-component aliphatic acrylic polyurethane topcoat with very good gloss retention and an excellent balance of hardness and flexibility.
Diagram code: JDThane7106S
Series: Anti-corrosive · Layer: Finish / topcoat
View productA fast-drying, one-component physically drying acrylic topcoat with a semi-gloss finish and good gloss retention.
Diagram code: JDAcrylic435
Series: Anti-corrosive · Layer: Finish / topcoat
View productA two-component solvent-free epoxy tank lining with good chemical resistance, qualified for potable-water contact.
Diagram code: 712SF
Series: Anti-corrosive · Layer: Tank lining (potable water)
View productTell us the substrate, service environment and area to be coated — we will confirm availability, lead time and the matching primer and topcoat.