C1–C3 covers clean interiors, rural atmospheres and moderate urban or industrial exposure. The dominant risk is moisture and moderate pollution — not salt spray or chemical immersion. Corrosivity is local to the steel, not to the country or the asset type.
Warehouses, light industrial frames, process buildings, dry stores and covered steelwork.
Durability is a target, not a promise. ISO 12944 durability bands — low, medium, high and very high — describe the intended time to first major maintenance under the defined environment. They do not replace the project specification, the coating build or the inspection plan.
| System | Primer | Intermediate | Topcoat | Build |
|---|---|---|---|---|
| C3-01 | H53-20 | — | SB52-30 | 2 coats |
| C3-02 | H04-C | — | JDAcrylic435 | 2 coats |
| C3-03 | H04-C | HY-1 | SB52-30 | 3 coats |
| C3-04 | C53-32 | — | JDAlkyd332 | 2 coats |
Role: Epoxy primer
Position: Primer
Moderate exposure. Measured protection.
Systems: C3-01
View productRole: Epoxy primer
Position: Primer
Moderate exposure. Measured protection.
Systems: C3-02 / C3-03
View productRole: Epoxy MIO intermediate
Position: Intermediate
Moderate exposure. Measured protection.
Systems: C3-03
View productRole: Aliphatic acrylic polyurethane topcoat
Position: Topcoat
Moderate exposure. Measured protection.
Systems: C3-01 / C3-03
View productRole: Acrylic topcoat
Position: Topcoat
Moderate exposure. Measured protection.
Systems: C3-02
View productRole: Alkyd anti-rust primer
Position: Primer
Moderate exposure. Measured protection.
Systems: C3-04
View productRole: Alkyd topcoat
Position: Topcoat
Moderate exposure. Measured protection.
Systems: C3-04
View productSa 2½; profile and cleanliness per the approved system sheet. Stripe-coat edges, welds and bolt heads before the full coat.
Do not leave an epoxy intermediate exposed to UV. Apply the topcoat within the approved overcoating window. Confirm steel temperature, dew point and dry film before the next coat.
The cheapest system is the one that reaches its next survey. A C3 system is not a place to remove the intermediate or shorten the surface preparation. The saving is visible at the quotation; the cost is visible at the first maintenance campaign.
Send the substrate, environment category, durability target and service temperature — we will return the matched build and the current TDS.